Kiepe Belt Misalignment Switches

Kiepe Belt Misalignment Switches are used in conveyor installations for monitoring belt travel. When mounted at the running edges of a conveyor belt, the switches engage if the belt deviates from its designed running line by more than the permissible distance.
On detection of unacceptable deviation Kiepe Belt Misalignment Switches stop the conveyor to avoid spillage of material or damage to equipment. All Kiepe Belt Misalignment Safety Switches are cam-operated and snap acting.
MRS
-
Used in conveyor installations for monitoring the true running of conveyor belts
-
Constructed from fibre reinforced plastic and stainless steel
-
Resistant to ammoniaOperates in extreme and harsh environments
-
Stainless steel roller (30 mm diam)
VG
-
Monitoring the true running of conveyor belts
-
Maintenance free
-
Switch enclosure consists of corrosion-resistant aluminium alloy
-
External parts are either of stainless steel or have been especially plated
-
The actuating roller is of polyamide
SEL
-
Designed for heavy duty application
-
Suited for controls and facilities according to EN 60204
-
Enclosure: Cast iron, EN-GJL-200
-
Admissible ambient temperature: –25°C … +70°CProtection
-
IP 67 according to EN 60529
SLS
-
Designed for heavy duty applications
-
Used at fixed belt conveyors
-
Complies with EN 60947-5-1
-
Admissible ambient temperature - 25 °C …+ 70 °C
HES
-
Designed for heavy duty applicationSuited for Controls and facilities according to EN 60204, Enclosure is Aluminum alloy GK-ALSi 12
-
Admissible ambient temperature: - 25 °C … + 70 °C
-
Extended temperature range: - 40 °C … + 70 °C for HES 711 model
-
Protection IP 65
HESEX
-
Suitable for controls and equipment acc. to EN 60204
-
Enclosure Aluminium, EN-AC-AISi 12
-
Permissible ambient temperature (VDE 0660): - 25 °C ^T amb ^+ 75 °C
-
Max. operating temperature of enclosure is 85 °CIP protection class
-
IP 65 acc. to EN 60529
MAS
-
Housing Ultramid A3EG5 (PA, fibre reinforced)
-
Protection IP 65 according to EN 60529
-
Rated insulation voltage Ui AC 250 V
-
Ambient temperature: - 25 °C … + 70 °C
-
Switching points: 10° and 25°Excursion: 90° max.